Dellon® 2-point Disk-Criminator™ 2 Disk Set Ideal for testing following nerve repair or to determine level of impairment.Accurately test two-point discrimination. Each disk in this two-disk set contains a series of metal rods with rounded points. Tips are spaced at varying intervals, from 1 to 15mm apart. A 20 and 25mm spacing also is given. Perfect for the home care therapist. Instructions are included. NC12752 Dellon® 2-point Disk-Criminator™ 2 Disk Set Email for Quotation
Disk-Criminator™
 

Dellon®Disk-Criminator™两点辨别觉测试盘二件装


Dellon®Disk-Criminator™两点辨别觉测试盘(Dellon® 2-point Disk-Criminator™ 2 Disk Set),是神经修复后的测试或神经损伤程度判定的理想工具,是国际公认的测试两点辨别觉的标准工具,测试得出的结果可以用于论文发布等。两磁盘中每个磁盘都包含一系列圆形金属杆,终端以1到15毫米不等的间隔隔开,也给出了20和25毫米的间隔。包括使用说明书。
利用Dellon®Disk-Criminator 两点辨别觉测试盘进行两点辨别觉检查,主要说明神经的支配密度,可进行静止的两点辨别觉(静态)与运动两点辨别觉(动态)的检查。

Dellon®Disk-Criminator 两点辨别觉测试盘为八边形,测定范围有两个,2-8mm和9-15mm。检查标准小于6mm为正常,相当于S4;7-11mm相当于S3+;12-15mm为差级。

神经再生时,首先恢复痛觉、温度觉,最后是实体感觉。对感觉的恢复有不同的诊断标准。
美国手外科学会利用两点辨别觉将感觉的恢复分为:
正常:小于6mm;
良:7-11mm;
不良:12-15mm;
保护性感觉:认为是一点;
麻木:不能认知;
英国医学研究会对感觉功能的评价提出判定标准为:
S0:神经支配区感觉完全丧失;
S1:有深部痛觉存在;
S2:浅表痛觉与触觉一定程度上存在;
S2+:浅表痛觉与触觉存在,有感觉过敏;
S3:浅痛觉触觉存在;
S3+:除S3外,有两点辨别觉(7-11mm);
S4:感觉正常,两点辨别觉(小于6mm),实体感觉存在。

原装进口
 

NC12752 Dellon®Disk-Criminator™两点辨别觉测试盘二件装 电邮询价



二点辨别觉测试演示视频(动态)
 


二点辨别觉测试演示视频(静态)





Dellon® 2-point Disk-Criminator™ 2 Disk Set Ideal for testing following nerve repair or to determine level of impairment.Accurately test two-point discrimination. Each disk in this two-disk set contains a series of metal rods with rounded points. Tips are spaced at varying intervals, from 1 to 15mm apart. A 20 and 25mm spacing also is given. Perfect for the home care therapist. Instructions are included. NC12752 Dellon® 2-point Disk-Criminator™ 2 Disk Set Email for Quotation
Dellon® 2-point Disk-Criminator™ 2 Disk Set Ideal for testing following nerve repair or to determine level of impairment.Accurately test two-point discrimination. Each disk in this two-disk set contains a series of metal rods with rounded points. Tips are spaced at varying intervals, from 1 to 15mm apart. A 20 and 25mm spacing also is given. Perfect for the home care therapist. Instructions are included. NC12752 Dellon® 2-point Disk-Criminator™ 2 Disk Set Email for Quotation
Dellon® 2-point Disk-Criminator™ 2 Disk Set Ideal for testing following nerve repair or to determine level of impairment.Accurately test two-point discrimination. Each disk in this two-disk set contains a series of metal rods with rounded points. Tips are spaced at varying intervals, from 1 to 15mm apart. A 20 and 25mm spacing also is given. Perfect for the home care therapist. Instructions are included. NC12752 Dellon® 2-point Disk-Criminator™ 2 Disk Set Email for Quotation
Dellon® 2-point Disk-Criminator™ 2 Disk Set Ideal for testing following nerve repair or to determine level of impairment.Accurately test two-point discrimination. Each disk in this two-disk set contains a series of metal rods with rounded points. Tips are spaced at varying intervals, from 1 to 15mm apart. A 20 and 25mm spacing also is given. Perfect for the home care therapist. Instructions are included. NC12752 Dellon® 2-point Disk-Criminator™ 2 Disk Set Email for Quotation
Dellon® 2-point Disk-Criminator™ 2 Disk Set Ideal for testing following nerve repair or to determine level of impairment.Accurately test two-point discrimination. Each disk in this two-disk set contains a series of metal rods with rounded points. Tips are spaced at varying intervals, from 1 to 15mm apart. A 20 and 25mm spacing also is given. Perfect for the home care therapist. Instructions are included. NC12752 Dellon® 2-point Disk-Criminator™ 2 Disk Set Email for Quotation
相关产品
上海瑞狮生物科技有限公司 Shanghai RuiShi Biological Technology Co., Ltd
版权所有 Copyright(C)2013-2025 沪ICP备15014599号